12 October 2025

Lenovo TS140 Hardware Upgrades

I decided to use my old server (Lenovo TS140) to replace my present one (Dell R730XD), There were two factors in my decision (1) it was more stable (2) it consumed less power at ~50W vs ~99W. However, before I could do that I wanted to make two key upgrades: (1) more than 4 cores/4 threads and (2) faster than gigabit networking.


Hardware Options

Processor:

  • E3-1225 v3 (Current Processor)
    • Links: Intel / Tech Power Up
    • 4 core 4 thread
    • Base: 3.2 GHz
    • Max Turbo: 3.6 GHz
    • IGP: Intel HD P4600
    • TDP: 84W
    • Single/Multi: 2014/5322
  • E3-1245 v3
    • Links: Intel / Tech Power Up
    • 4 core 8 thread
    • Base: 3.4 GHz
    • Mz Turbo: 3.8 GHz
    • IGP: Intel HD P4600
    • TDP: 84W
    • Single/Multi: 2150/7044
  • E3-1275 v3
    • Links: Intel / Tech Power Up
    • 4 core 8 thread
    • Base: 3.5 GHz
    • Max Turbo: 3.9 GHz
    • IGP: Intel HD P4600
    • TDP: 84W (listed as 95W at places)
    • Single/Multi: 2198/7203


NIC:
  • Used Intel X710-DA2
    • roughly $30 from eBay
    • 10 Gbps SFP+
    • Requires a PCIe x8 slot
  • Realtek RTL8125B NIC
    • roughly $17-20 from Amazon
    • 2.5 Gbps
    • Requires a PCIe x1 slot (PCIe 2.0 x1 provides up to 5 Gbps of bandwidth)


Decision

I went with the E3-1275 v3 as it was roughly the same price as the E3-1245 v3 and was slightly faster.

I chose the Realtek RTL8125B from GiGaPlus as it would keep the x16 slot free in my TS140 for future expandability. I also only had a single free SFP+ port on my switch,


Appendix

Sources


14 September 2024

Adding a USB card to Dell r730xd

As I was tired of being limited to just 2 USB ports, I picked up the Inateck RedComets U21 20Gbps on Prime Day for $31.99 plus tax.


Specs

  • 2 lanes of PCIe 2.0/3.0/4.0 (3.0 or 4.0 required for full speed)
  • Max combined throughput 16 Gbps
  • 10 Gbps dedicated port
    • USB-A
  • 10 Gbps split between
    • 2 x USB-A
    • 2 x USB-C


Add USB Card

  • Shutdown containers and VMs
  • Turn off the server
  • Install the USB card
    • I installed it above the 2.5" drive bays in the back in Riser 3 (Slot 6)
  • Turn on the server
  • Fix fan speed
    • apt-get install ipmitool
    • ipmitool -I lanplus -H 192.168.1.X -U root -P <password> raw 0x30 0xce 0x00 0x16 0x05 0x00 0x00 0x00 0x05 0x00 0x01 0x00 0x00
    • response:
      • 16 05 00 00 00
  • Shutdown the VM you want to add it to
  • Add the USB Card to a VM
    • Select your VM -> Hardware -> Add -> PCI Device
    • Select Raw Device -> Device: ASM2142/ASM3142 USB 3.1 Host Controller
    • Check All Functions
    • Add
  • Start the VM
  • Check that it is working
    • lsusb -t


Test a USB hard drive

  • plug in the USB hard drive
  • determine what drive letter it is:
    • ls -l /dev/disk/by-id
  • Mount it
    • sudo mount -m /dev/sdb1 /mnt/backup-plus
  • Error: unknown filesystem type 'exfat'
    • sudo apt-get install exfat-fuse
    • sudo mount /dev/sdb1 /mnt/backup-plus -t exfat-fuse


Appendix

Sources

Setting up a Jellyfin media server

I wanted to install a media server to help manage my growing library. The top two options that I found are Plex and Jellyfin. I have used Plex in the past, but disliked when they started requiring an account so I went with Jellyfin.


Create the container

  • bash -c "$(wget -qLO - https://github.com/tteck/Proxmox/raw/main/ct/jellyfin.sh)"


Set Static IP and hostname

  • Proxmox -> jellyfin -> Network -> net0 -> Edit
    • set static ip
  • Restart the container
  • Proxmox -> jellyfin -> Console
    • ping 192.168.1.1
      • this ensures that the container will show up on Unifi's list of clients
  • Unifi -> Clients -> Select the jellyfin -> Settings
    • give it a memorable name
    • check "Fixed IP Address"
      • it should auto-populate with current IP
    • check "Local DNS Record"
      • jellyfin.home.arpa


Setup Jellyfin

  • Self signed SSL certificate:
    • https://jellyfin.org/docs/general/networking/
    • jellyfin -> Console
      • mkdir -p /home/jellyfin
      • cd /home/jellyfin
      • openssl req -x509 -days 3650 -newkey rsa:4096 -keyout ./privkey.pem -out cert.pem -nodes -subj '/CN=jellyfin.home.arpa'
        • -subj '/' can work if you can override ssl verification on the client, but Kodi doesn't have that option
        • -subj '/CN=localhost' was causing jellyfin to crash here are some keywords from the crash:
          • Error occurred during a cryptographic operation
          • MapOpenSsl30Code
      • openssl pkcs12 -export -out jellyfin.pfx -inkey privkey.pem -in cert.pem -passout pass:
      • chown -R jellyfin /home/jellyfin
      • chgrp -R jellyfin /home/jellyfin
  • http://jellyfin.home.arpa:8096
    • create user/pass
    • hamburger menu -> Dashboard -> Networking
      • Check "Enable HTTPS"
      • Check "Require HTTPS"
      • Custom SSL certificate path -> /home/jellyfin/jellyfin.pfx
      • Save
  • Restart the jellyfin container
  • Test the self-signed certificate
    • curl --cacert cert.pem https://jellyfin.home.arpa:8920
  • https://jellyfin.home.arpa:8920
    • hamburger menu -> Dashboard -> Users
      • Add User
      • Name
      • Password
      • Check "Enable access to all libraries"
    • hamburger menu -> Dashboard -> Plugin -> Catalog -> Kodi Sync Queue
      • Install
    • Restart jellyfin


Add to Kodi on Google TV

  • Have Kodi trust the self signed certificate
  • Enable adb (Android Debug Bridge)
    • Determine IP of the Google TV
      • Settings -> System -> About -> Status
    • Enable Developer mode
      • Settings -> System -> About -> Build Number -> Click 10 times or until developer mode is unlocked
    • Enable USB debugging (also enables remote debugging)
    • install adb onto a computer to be able to modify the Google TV remotely
      • sudo apt install android-tools-adb
  • Used adb to add new certs file to existing
    • adb pull /sdcard/Android/data/org.xbmc.kodi/files/.kodi/addons/script.module.certifi/lib/certifi/cacert.pem
    • cat cacert.pem cert.pem > updatedcacert.pem
    • adb push updatedcacert.pem /sdcard/Download/
    • echo -e '<advancedsettings version="1.0">\n<network>\n<catrustfile>special://masterprofile/updatedcacert.pem</catrustfile>\n</network>\n</advancedsettings>' >advancedsettings.xml
    • adb push advancedsettings.xml /sdcard/Download/
  • Have Kodi use the new certs
    • Google TV -> Settings -> Apps -> Kodi -> Permissions -> Files and Media -> Allow management of all files
    • Kodi -> Settings -> File Manager
      • Left Side
        • Add Source -> Browse -> External Storage -> Download -> OK
        • Open Download
      • Right Side
        • Profile directory
      • Long press the files one at a time in the Left pane and select copy
    • Restart Kodi
  • Install Jellyfin on Kodi
    • Kodi -> Settings -> File Manager -> Add Source
      • https://kodi.jellyfin.org
    • Kodi -> Settings -> AddOn Browser
      • Allow install from unknown sources when prompted
      • Install from zipfile -> jellyfin -> repository.jellyfin.kodi.zip
      • Install from Repository -> Kodi Jellyfin Add-ons -> Video Add-ons
      • Select Jellyfin add-on and install
    • Cancel adding the server
    • Disable "Verifiy connection" -> OK
    • Restart Kodi
    • Select Manual server add (as auto does it by IP)
      • https://jellyfin.home.arpa:8920
      • sign in using user/pass
      • Playback -> Addon (default)
      • Choose which libraries you want to sync
        • click "All"
        • click "OK"
    • After Syncing is complete restart Kodi
    • Settings -> Add-ons -> My add-ons -> Video add-ons -> Jellyfin
      • Configure -> Sync -> Enable Kodi Sync Queue -> OK


Appendix

Sources

15 July 2024

Intel SSD upgrade for r730xd

I got 2 used intel ssds to improve VM performance and to reduce power usage


Check SMART attributes


Firmware Update Adventure

Intel Memory and Storage Tool CLI

My first attempt was to use Intel cli to update the firmware, but it did not work.


Solidigm

My second attempt was to use Solidigm cli to update the firmware, but it did not work through the raid controller and had to be attached to a different SATA controller.

  • Installation
  • Usage
  • Firmware Update
    • sst load -ssd <index>
    • Status : Firmware update failed.
      • If your drives are behind a RAID card, you may have to remove them for updating.
  • Firmware Update using a USB to SATA enclosure
    • sst show -ssd
    • Unfortunately, the drive no longer appeared :-(
  • Firmware Update using Windows with USB to SATA enclosure
    • The drive appeared and would run tests
    • However attempting to update the firmware resulted in an error and the USB port being disabled until the PC was rebooted
  • Firmware Update using a JMB585 PCIe to SATA card, a SATA to eSATA bracket, and an external eSATA enclosure
    • Finally was able to update the firmware
    • Notes:
      • the firmware did not jump to the latest version and had to be updated incrementally
        • G2010140 -> G2010160 -> G2010170
      • the firmware update requested a reboot after installing so I did that
    • sst show -ssd
    • sst show -a -ssd <index> | grep Firmware
    • sst load -ssd <index>
    • Status : Firmware updated successfully. Please reboot the system.


Replacing the existing 1.2 TB drives

  • Setup the partitions
    • I used my rpool mirror instructions from here but made the following changes
      • removed the last-lba line
      • removed the start from all lines
      • removed the size from the final partition
      • don't run the zpool attach
  • Copy the rpool data
    • I am following the wizardry provided here
    • Add a mirror of the new disks to form a striped mirror
      • zpool add rpool mirror /dev/disk/by-id/ata-INTEL_SSDSC2BX800G4_<SERIAL1>-part3 /dev/disk/by-id/ata-INTEL_SSDSC2BX800G4_<SERIAL2>-part3
    • Check the mirror names and size
      • zpool status rpool
      • zpool list rpool
    • Remove the old mirror
      • zpool remove rpool mirror-0
    • Check for when "Evacuation of mirror" is done
      • zpool status rpool
      • remove: Removal of vdev 0 copied 10.7G in 0h1m
    • Check new size
      • zpool list rpool
  • Shutdown and remove the drives and reboot to make sure everything is working as intended
  • Remove the old drives from proxmox-boot-tool
    • proxmox-boot-tool status
    • proxmox-boot-tool clean
    • proxmox-boot-tool status
  • Remove all data from old drives
    • put the drives back in
    • wipe them using your favorite tool (eg. shred or dd)
      • dd if=/dev/zero of=/dev/sdX -bs=1M status=progress
      • dd if=/dev/urandom of=/dev/sdX -bs=1M status=progress


Conclusion

I saw a 7-8W drop in idle power usage and an increase in responsiveness.


Appendix

Sources


05 June 2024

r730xd Server Part 2: Lowering Idle Power

 As the plan is to have the server on 24/7, I wanted to lower the idle power usage. All power numbers were manually captured from a smart outlet.


Baseline

1 x e3-1225v3, 4 x 8GB, 1 SSD, 2 x WD Red Plus 6TB, 1 x JMB585

  • in Ubuntu no load
    • ~35W

2 x e5-2670v3, 8 x 16GB, 1 x 10K 2.5" SAS

  • in Proxmox no load
    • ~95W (93.6 to 100)
    • 4% fans
  • stress -c 48
    • 290W
    • 8% fans
    • 70C + 77C (inlet 16C, exhaust 39C)


Removing a processor

This will lower the PCIe connectivity, but should save power. To be able to remove a processor, I needed to buy a CPU socket cover and an airflow guide

  • Socket 2011-3 cover: $6.99 + tax
  • Dell CPU Blank airflow guide 21PJD: $11.02 + tax
    • Note: this will not allow you to install blanks into the memory slots so dust could be an issue
  • Updated total: $452 + tax

1 x e5-2670v3, 4 x 16GB, 1 x 10K 2.5" SAS

  • in Proxmox no load
    • ~81W (80.5 to 85.4)
    • 4% fans
  • stress -c 24
    • 166W
    • 8% fans
    • 67C (inlet 15C, exhaust 27C)

1 x e5-2670v3, 8 x 16GB, 1 x 10K 2.5" SAS

  • in Proxmox no load
    • ~82W (81.4 to 85.2)
    • 4% fans
  • stress -c 24
    • 174W
    • 8% fans
    • 68C (inlet 15C, exhaust 27C)

This means that the memory used only about ~1W at idle for all 4 sticks and ~8W at full load. This means that running a single processor will save me about 13W.


Adding a second drive

Adding the second 1.2TB SAS drive increased my idle power usage by ~4.5W

  • in Proxmox no load
    • ~86.5W
    • 4% fans


Making the jump from a Xeon v3 (22nm) to v4 (14nm)

For this upgrade I bought used processors

  • 2 x 2680 v4: $21.58 + tax
  • Updated total: $474 + tax

I moved from a 2670 v3 to a 2680 v4 in hopes that it would shave off a couple of watts at idle, unfortunately it uses ~1.5W more. So it seems that each core uses about 1W at idle.

  • in Proxmox no load
    • ~88W (87.4 to 89.1)
    • 4% fans
  • stress -c 28
    • 205-206W
    • 80C (inlet 17C, exhaust 30C)

While not improving the idle power usage, it will be a large boost in both single-core (13%) and multi-core performance (23%) https://www.cpubenchmark.net/compare/2779vs2337/Intel-Xeon-E5-2680-v4-vs-Intel-Xeon-E5-2670-v3


Setting governor to powersave

Tried changing the governor to save idle power, but did not notice any change.
  • apt-get install linux-cpupower
  • cpupower frequency-set -g powersave


Appendix

Sources

17 April 2024

r730xd Server Part 1: Initial Build

In order to support more than the 2 hard drives I could in the TS140, I needed a new system. Here were my requirements:

  • price < $500
  • reasonable noise level
  • more than 4 cores
  • ECC RAM (preferably at least 128GB)
  • 8 or more spots for hard drives

I was looking at some older SuperMicro and Dell systems. I read several posts about the power supplies being louder on the SuperMicro so I decided to go with the Dell r730xd that supports 12 x 3.5" drives in the front and 2 x 2.5" drives in the rear.


Hardware

  • r730xd used - $350 + tax
    • 2 x e5-2670v3 12 cores each
    • 128 GB ECC DDR4 (8 x 16GB)
    • PERC H730p Mini raid controller
    • 1 x 2.5" caddie with 1.2TB 10K SAS drive
    • iDRAC 8 Enterprise license
  • 12 x 3.5" used caddies - $60 + tax
    • SAS or SATA caddie both work for holding sata drives
  • 1 x 2.5" caddie with 1.2 TB 10K SAS drive - $24 + tax
    • this is a second drive for a boot mirror
  • total: $434 + tax


TLDR; Pros/Cons

  • Pros
    • Many many cores
    • Loads of RAM with expandability
    • Thermal solution works quite well even under full load with fans at 6-8% (2640-2880 rpm) on auto keeping the processors around 77C
    • iDRAC is quite useful especially the HTML5 virtual console (requires Enterprise license)
  • Cons
    • No hardware reset for iDRAC
  • Somewhere in the middle
    • idle power usage of 94-96W (with a single 2.5" drive) is higher than I would like
      • Fans @ 4% (2280 rpm)
      • 18W for iDRAC even when powered down
    • installing hard drive
      • when installing an older drive (250GB WD) fans spun up to 40% (7320 rpm), this may have been because it was unable to read temp or was failing
      • installing a 3TB WD Red drive caused the fans to go to 6% (2680 rpm)
    • Fan noise
      • 45-50% (8880-9840 rpm) is noticeable with the basement door closed
      • 30% (6480 rpm) is noticeable with the basement door open
      • 15-20% (4080-4920 rpm) about as loud as a running fridge
      • 10% (3240 rpm) a low constant hum
      • 6% (2640 rpm) quieter than seeking dvd drives


BIOS/iDRAC reset and setup

First I did a BIOS reset by moving the jumper. Unfortunately, this did not reset the iDRAC, and there does not seem to be a way to do this with hardware. For this you will need a VGA monitor and keyboard. I followed this video to do it: https://www.youtube.com/watch?v=R5pYfqDtzQw

Reset BIOS

  • F2 for System Setup
  • System BIOS
  • Default
  • Finish and Confirm
  • Reboot

BIOS Settings to change from default

  • Boot Settings -> Boot Mode -> UEFI
  • System Profile Settings -> System Profile -> Performance per Watt (OS)
  • Integrated Devices -> USB 3.0 Setting -> Enable (Added 2024-06-07)
  • Finish and Confirm
  • Reboot

Reset iDRAC

  • F2 for System Setup
  • iDRAC Settings
  • Reset iDRAC configurations to defaults
  • Finish and Confirm
  • Reboot

Then I was able to configure iDRAC from its default 192.168.0.120 to an unused IP on my network.

  • F2 for System Setup
  • iDRAC Settings
  • Network
  • Update Static IP Address (and Subnet/Gateway if applicable)
  • Back
  • Finish and Confirm
  • Reboot


Memory Testing

While memtest86 isn't the best memory tester available, it is free and doesn't require an OS to be installed. I used version 10.7, which I downloaded the ISO for loading onto my Ventoy USB from here: https://www.memtest86.com/downloads/memtest86-iso.zip

It took about 24 hours to do all 4 passes of the test patterns.


Update iDRAC

Here is where I downloaded the iDRAC update from: https://www.dell.com/support/home/en-us/product-support/product/poweredge-r730xd/drivers. You should download the version for windows for uploading through the Web UI. Then apply the updates from the iDRAC interface: Login to iDRAC -> iDRAC Settings -> Update and Rollback -> upload

At first I download the win64 version of the latest available (2.85.85.85), but the update would fail due to it not validating. Here is the update path that I went with: 2.61.60.60 -> 2.63.60.61 (win32) -> 2.75.100.75 (win32) -> 2.85.85.85 (win64)

After the first update the iDRAC appeared to be unresponsive, so I let it sit for ~20 minutes and it was still unresponsive, however I could ping it. At this point I held in the "i" button for ~20s to restart the iDRAC. This brought it back to life.

Here is a video that I found helpful: https://www.youtube.com/watch?v=dea-PA1na0c


Update the rest of the firmware

I always update the BIOS separately

Update BIOS/UEFI:

  • Login to iDRAC -> iDRAC Settings -> Update and Rollback -> HTTPS
  • HTTPS Address: downloads.dell.com
  • Check for Updates
  • Select the BIOS update and click "Install and Reboot"
  • The system will then reboot and install the new BIOS

Update Raid/Network:

  • Login to iDRAC -> iDRAC Settings -> Update and Rollback -> HTTPS
  • HTTPS Address: downloads.dell.com
  • Check for Updates
  • Select the Raid and Network update and click "Install and Reboot"
  • The system will then reboot and install the new BIOS


Set Raid card to HBA mode

This will pass the drives directly to the OS to manage the software raid.

Login to iDRAC -> Storage -> Controllers -> Setup -> Controller Mode -> Action -> HBA


Proxmox install

I downloaded Proxmox 8.1 from: https://www.proxmox.com/en/downloads

I was using a Ventoy USB to do my Proxmox 8.1 install, but it was giving me an error. However, I found that you need to use Ventoy >= 1.0.97 (https://github.com/ventoy/Ventoy/releases/tag/v1.0.97). So I updated my Ventoy USB and then the install proceeded.

During the setup here are some of the values that I chose:

  • Target -> Options
    • If you only have 1/2 of your boot drives
      • ZFS (RAID0)
      • Harddisk 0 - 1.09TB
      • Harddisk 1 - Do not use
    • If you have both go ahead and setup the mirror
      • ZFS (RAID1)
      • Harddisk 0 - 1.09TB
      • Harddisk 1 - 1.09TB
  • Timezone: America/New_York
  • Password and Email
  • Management
    • Make sure to select the correct management interface (easier if network is hooked up before starting setup)
    • Hostname: r730xd.home.arpa
    • IP Address: pick a free IP
    • Gateway/DNS

After the setup, login to the web ui: https://<IP>:8006

  • Disable Proxmox Enterprise repos as they require a license
    • Click on the hostname (r730xd)
    • Remove the subscription update repository
      • Updates -> Repositories
      • Highlight "pve pve-enterprise" and click "Disable"
      • Highlight "ceph-quincy enterprise" and click "Disable"
    • Add the No Subscript update repository
  • Update your install
    • Updates
    • Click "Refresh"
    • Close the window when it is done
    • Click "Upgrade"
    • Type "y" and enter


Add the rpool mirror (if not configured at install)

  • Determine if using grub or systemd-boot
    • proxmox-boot-tool status
    • efibootmgr -v
  • Copy the partition table over (removing disk label-id and uuids so sfdisk generates new ones)
    • sfdisk -d /dev/sda > part_table
    • sed -e '/^label-id:/d' -e 's/,\s*uuid=[-0-9A-F]*//g' part_table | sfdisk /dev/sdb
  • Copy the bios boot
    • dd if=/dev/sda1 of=/dev/sdb1
  • Prepare EFI partition
    • dd if=/dev/sda2 of=/dev/sdb2 Don't do this as it keeps the UUID
    • OR
    • proxmox-boot-tool format /dev/sdb2
  • Initialize the EFT partition
    • proxmox-boot-tool init /dev/sdb2
    • OR if using grub
    • proxmox-boot-tool init /dev/sdb2 grub
  • Get current zpool drive
    • zpool status
  • Add the mirror
    • zpool attach rpool scsi-XXXXXXXXX-part3 /dev/disk/by-id/scsi-YYYYYYYYY-part3
  • ZFS will then resilver the drive, to check if done run
    • zpool status


intel_pstate

Trying to lower the idle power usage, I wanted to try a different cpu governor driver.
  • check whether it is intel_pstate or intel_cpufreq
    • apt install cpufrequtils
    • cpufreq-info | head -n 13
  • Determine if using grub or systemd-boot
    • proxmox-boot-tool status
    • efibootmgr -v
  • to enable intel_pstate for grub boot:
    • edit /etc/default/grub
    • add intel_pstate=active to GRUB_CMDLINE_LINUX_DEFAULT
      • example: GRUB_CMDLINE_LINUX_DEFAULT="quiet intel_pstate=active"
    • proxmox-boot-tool refresh
    • wait for grub to finish updating and then reboot
  • to enable intel_pstate for systemd-boot
    • edit /etc/kernel/cmdline
    • add intel_pstate=active to the end
    • proxmox-boot-tool refresh
    • wait for it to update and then reboot
  • ensure it is now intel_pstate
    • cpufreq-info | head -n 13
  • unfortunately this did not change idle power usage


Fan Information

Here are the fan values from my r730xd

  •  4% -> 2280 rpm -> 10 cfm
  •  6% -> 2640 rpm -> 12 cfm
  •  9% -> 3000 rpm -> 18 cfm
  • 12% -> 3600 rpm -> 21 cfm
  • 15% -> 4080 rpm -> 24 cfm
  • 20% -> 4920 rpm -> 30 cfm
  • 25% -> 5640 rpm -> 36 cfm
  • 30% -> 6480 rpm -> 41 cfm
  • 40% -> 7320 rpm -> 53 cfm
  • 50% -> 8160 rpm -> 64 cfm


Appendix

Sources